6. rt = repeat
This command will tell the machine to repeat the previous command. The
command line takes a repeat count, and flags whether or not to ignore
errors. It also flags wether or not to show the command line of the command
to be run. The command line consists of one or more commands separated
by semicolons. The entire command line must be enclosed within double
quotes. Each command within the command line consists of a name and its
parameters. The command line is run until the iteration count is reached or
an error occurs. For each iteration, each command within the command line
is run in the order in which it appears.
Parameters:
Example: rt 20 1 tm
-438
The command RT 1000 0 tm will help troubleshoot temperature
issues in maintenance mode only.
The command RT 100 0 fh or RT 100 0 fz will help verify any X/Y/Z
sensors that had issues before the repair are tested and operational.
signed integer count
signed integer ignoreErrors
string commandLine
This parameter specifies the number of times the
command is to be run.
This parameter specifies whether errors should be
ignored. A value of zero causes the test to stop
when an is encountered A value of one causes
the test to run for the full count even when errors
occur.
This parameter contains the command line of the
command to be run enclosed within double
quotes. A commandline includes the name of the
command followed by it's parameters.
Figure 443: Repeat