Code
Description
14,05
Abort : Unexpected
contact with X axis
home sensor.
14,06
Abort : Unexpected
contact with X axis EOT
sensor.
14,07
Abort : Unexpected
contact with Y axis
home sensor.
14,08
Abort : Unexpected
contact with Y axis EOT
sensor.
14,09
Abort : Unexpected
contact with Z axis
home sensor.
14,10
Abort : Unexpected
contact with Z axis EOT
sensor.
14,1 1
Abort : Door opened
while axis in motion
14,13
Abort : Under Run at
vertex buffer
14,14
Abort : Under Run not in
tool path
14,15
Report: Head motor
running without XY
motion
14,16
Abort : Vertex FIFO tail is
not on a 4 byte
boundary.
14,17
Abort : User abort.
14,18
Abort : User panic stop. 1. Will not be displayed on LCD (Opening
Corrective Actions
1. Power cycle the machine.
2. Check for an obstruction hitting the model.
3. Check to make sure the homing sensors are
clean.
4. Using LED's check if home & limit boxes are
lit. If so, check limit switches and/or
Umbilical Cable for X sensors, Y cable for
Y sensors.
5. Manually move the XY table in X and Y
checking for smooth operation.
6. Check belt tension.
7. Replace XY table. Failed bearings in the Y
drive shaft possible root cause
1. Check to see if the switch is operating
correctly using the LED/test points on the
PDB.
2. Check to see if there are any obstructions
interfering with Z stage movement.
1. Check to see if door latch is activating using
LED's.
2. Check J504 pins 8 and 20 on the I/O card
for loose contacts or bent pins.
3. Look at LCD display, should show "Door
Open" when machine is idle and door is
open.
4. Using LED's check to see "Door Open"
toggles when switch is activated. If not,
check door switch and/or Mid-Unit
Harness.
5. Wiggle the door, make sure the sensor
reads the magnet with movement to the
door.
6. Check that the door magnet is present.
1. Reprocess the part and send again.
2. Reorient the STL and resend.
3. If the frequency of the error is greater than
once every three months, then replace the
SBC or hard drive.
1. Software use only.
1. Communication error between controller
board and the SBC - Power cycle system
2. Reseat the controller board into SBC.
3. Replace controller board and/or SBC.
1. Build was cancelled through the keypad.
door during build can cause this error).