Performing part based calibration for HP Designjet 3D with the HP Designjet
3D Diagnostic Software
1. Open HP Designjet 3D Diagnostic Software and select the current
2. Open Gantry Calibration Dialog box in HP Designjet 3D Diagnostic
3. Set the X adjust value to 0.
4. In the Part Calibration section, there are six boxes: LEFT, RIGHT, FRONT,
5. Click on the green check mark to save the values.
6. Toggle the system power down switch.
7. Once the system displays Idle, press Maintenance>System>Test Parts
8. When part is completed, remove from printer and let cool for five min-
9. Locate the filled circle, this indicates the front of the substrate, see
10. Using a digital caliper, measure and record the diameter of circle B
-352
modeler from the pull down menu.
Software
REAR, LEFT FRONT and LEFT REAR. Set these values to 0.
then select the test_XY_cal part.
utes.
338
Figure 338: Locating the Filled Circle (B)
along the center line between A and C, see
NOTE: Reference letters are not actually "printed" on the part. If
needed, use the Part Measurement Equations sheet to record the
values. See
"Part Measurement Equations" on page 359.
Figure
Figure 339