Complete The Re-Assembly Of The Toggle Head Assembly - HP Designjet 3D Service Manual

Hide thumbs Also See for Designjet 3D:
Table of Contents

Advertisement

Figure 416: Liquefier alignment check (2 of 2)

Complete the Re-Assembly of the Toggle Head Assembly

1. Connect the Filament Tubes to the top of the Toggle Head Assembly -
make sure the model tube is on the right; the support tube on the left.
2. Install the Air Plenum - connect the Plenum to the air duct at top - press in
on clips to fit the plenum to the Translator.
3. Install the Head Cover - squeeze the side tabs to fit the Translator.
4. Power the printer up.
5. From the display panel, press Maintenance > System > Tips and perform
the following calibrations:
A. Z calibration
B. XY Tip offset calibration.
NOTE: Follow the Head Installation Checklist after completing
Toggle Plate Assembly replacement.
Unacceptable liquefier
alignment
Pinch point is the same
as the centerline of the
alignment rod.
-401