Controller Initialization Failed Minor Errors (19.XX)
Code
Description
19,01
IN_COMMAND Rejected by
Controller.
19,02
IN_COMMAND Timeout.
Door Unlatch Failed (20.XX)
Code
Description
20,01
Unlatch command rejected.
20,02
Timeout period expired waiting
for head to stop.
Controller Communications Failed Sub Errors (22.XX)
Code
Description
22,01
FC_SERVICE event not received.
22,02
Insufficient material to complete job.
Universal Device Name Error (23.XX)
Code
Description
23,01
UDN controller command failed.
23,02
UDN controller command timed
out.
Corrective Actions
Software use only
1. Cycle power.
2. Replace controller board.
3. Replace hard drive.
Corrective Actions
1. Check door latch solenoid wiring.
2. Check ability of door to latch
Corrective Actions
Not used on HP Designjet 3D
printers
Corrective Actions
1. Check network for connectivity.
2. Cycle power.
-106