3. Press the Edit Configuration button.
4. Press the Next... button.
5. Press the Next... button.
6. Press the XTIP (X tip offset) button.
7. Enter the calibration value by pressing the Increment, Decrement and
8. When finished, press Done...
9. Press the YTIP (Y tip offset) button.
10. Enter the calibration value by pressing the Increment, Decrement and
1 1. When finished, press Done...
12. Press the Next... button until you reach the last page.
13. Press the Done... button.
14. Press the Save and reboot button.
15. The printer will reboot and return to idle.
16. Perform automatic XY Tip Calibration, see
-342
Figure 321: Service Calibration button sequence
Button 0
Button 1
Button 2
Button 3
Next Digit buttons.
NOTE: The value for XTIP must be between 0.7300" and 0.8300",
For example, the value from
the current value by +0.002".
Next Digit buttons.
NOTE: The value for YTIP must be between -0.0500" and 0.0500",
For example, the value from
the current value by -0.004".
page 340.
Figure 320
is + 2, you would increment
Figure 320
is - 4, you would decrement
"XY Tip Calibration" on