Checking/Adjusting the X-Drive Belt Tension
1. Remove the top and side panels.
2. If required, allow system to cool to room temperature (approximately 20
3. Move the Head Assembly to the full right travel position within the build
4. Position the dial indicator on the rear section of the X-Drive belt - cen-
5. Check the tension:
-382
minutes).
envelope (as viewed from the front of the printer).
tered between the Head Assembly and the left side of the build enve-
lope.
(Figure
395)
Figure 395: X belt tension location
(Figure
The large hand on the gauge should read between 25 and 35 mils, and
the small hand should read between 4 and 5.
396)