Z Tip To Tip (Zt2T) - HP Designjet 3D Service Manual

Hide thumbs Also See for Designjet 3D:
Table of Contents

Advertisement

Figure 319: Service Calibration button sequence
Button 0
Button 1
Button 2
Button 3
3. Press the Edit Configuration button.
4. Press the Next... button.
5. Press the Next... button.
6. Press the ZT2B (Z tip to base) button.
7. Enter the calibration value by pressing the Increment, Decrement and
Next Digit buttons.
NOTE: The value for ZT2B must be between -0.1500" and
0.0000".
8. When finished, press Done...
9. Press the Save and reboot button.
10. The printer will reboot and return to idle.
1 1. Perform automatic Z calibration. See

Z tip to tip (ZT2T)

ZT2T is the Z distance from the model tip to the support tip. A positive ZT2T
means the support tip is higher than the model tip. If a support layer on top
of model is too thick, add 0.010" to the ZT2T. If a model layer does not
stick to supports, subtract 0.010" from the ZT2T.
automatically, this value may need to be set to default in order to proceed
with automatic calibration. The default value is 0.0000".
1. While the printer is at Idle, enter standby mode by pressing the
Standby... button.
2. Enter the Service Calibration menu by pressing the following button
sequence on the display panel: 3,2,3,3,1. See
3. Press the Edit Configuration button.
"Z Calibration" on page 338.
If unable to calibrate
 
Figure 319.
-339