23.3.5
AC Characteristic Test Conditions
The AC characteristic test conditions are as follows:
Input/output signal reference level: 1.5 V (V
Input pulse level: V
Input rise/fall time: 1 ns
The output load circuit is shown in figure 23.74
LSI output pin
Notes: 1.
C
is the total value, including the capacitance of the test jig, etc.
L
The capacitance of each pin is set to 30 pF.
2.
I
and I
OL
OH
Rev. 3.0, 04/02, page 1028 of 1064
–3.0 V (V
–V
SSQ
SSQ
DDQ
C
L
values are as shown in table 23.11, Permissible Output Currents.
Figure 23.74 Output Load Circuit
= 3.3 ±0.3 V)
DDQ
for
,
, NMI, and
I
OL
I
OH
/BRKACK)
DUT output
V
REF