Select (Edit Menu); View Menu; Fit Automatically (View Menu); Select Zoom Area (View Menu) - Siemens SIMATIC BATCH Operating Manual

Process control system pcs 7
Table of Contents

Advertisement

Note
When hiding target target interconnections the parameter name of the target interconnection
is automatically renamed.
In a flat recipe set up a target interconnection between header and function parameters; the
parameter name remains unchanged and thus remains unique. If you hide the function within
a substructure, the parameter name of the target interconnection is overwritten by the original
name of the variable.
14.3.2.12

Select (Edit menu)

Function
Using this function in the BATCH Recipe Editor, you can change the Edit mode to the Select
mode. There are two ways of selecting an object (structure element) in the recipe:
● Click the required object to select it
● Drag a lasso around the required object to select it.
Additional information
Selecting objects (Page 499)
14.3.3

View menu

14.3.3.1

Fit automatically (View menu)

Function
In the BATCH Recipe Editor and in batch control, this function adapts the display of a recipe
in the active work window automatically to the window size (checked) if you change the size
of the area being used.
14.3.3.2

Select zoom area (View menu)

Function
Use this function in the BATCH Recipe Editor and for batch control to adjust the zoom factor
of the display in the active work window to the selected area.
SIMATIC BATCH V8.2
Operating Manual, 02/2016, A5E35958174-AA
Context help references
14.3 RE menu commands
1101

Hide quick links:

Advertisement

Table of Contents
loading