Siemens SIMATIC BATCH Operating Manual page 1022

Process control system pcs 7
Table of Contents

Advertisement

Context help references
14.1 Dialogs
Properties
Name of the object selected in the navigation tree.
Description
Created by
Equipment module
Buttons
Check validity
Update
New
Delete
Log
"Errors" display field
"Warnings" display field
"Display" button
Additional functions
Display instances: Opens a dialog displaying all objects contained in the previously selected
object.
1022
Any object description by the user.
Specification of the application that created the object, either SIMATIC
BATCH PCell Control Center or SIMATIC Manager:
● If a type object was created by SIMATIC Manager, additional subobjects
cannot be added, nor can the selected object be deleted or changed,
either via the PCC API or with the PCC configuration dialog.
● If an instance object was created by SIMATIC Manager, additional
subobjects can be added via the PCC API or with the PCC configuration
dialog. However, it is still not possible to delete or change the selected
object here.
All batch instances, starting with the selected object (here, an equipment
module), are checked for consistency with batch types and for conformity
to ISA-88. The validity errors and validity warnings are displayed in the log
field and can be visualized using the "Display" button.
All batch instances are adapted according to the batch types. This action
is always required if a change has been made to batch types of existing
batch instances (e.g., inserting a new parameter, changing the unit of
measure, etc.).
A new subobject is created below the selected "Equipment module" object.
The possible object types are offered in the subsequent dialog "Insert" for
selection.
The equipment module object can be deleted here. All subobjects (phase
blocks) are implicitly deleted. Deletion is only possible if the selected object
is not in use.
The number of errors for the selected log is displayed.
The number of warnings for the selected log is displayed.
The logging is activated with the "Display" button. The selected log is
generated as an XML file in the specified layout and displayed in In‐
ternet Explorer.
Select "Process cell" and click the "Display" button to show all process
cell errors or warnings. You can also right-click a selected object and
select the "Display log" function to display object-specific errors or
warnings.
SIMATIC BATCH V8.2
Operating Manual, 02/2016, A5E35958174-AA