General Description
The Variable Timing Parameters feature gives the PBX the versatility to change timing parameters, using
the MAINTENANCE ADMINISTRATION TERMINAL (MAT) [M-18]. All timing parameters for a specific
timing sequence are set initially within the generic program. These timing parameters can be changed to
accommodate user requirements.
Operating Procedure
No manual operations required. Refer to the NEAX2400 ICS Command Manual.
General Description
The following list describes the major VARIABLE TIMING PARAMETERS:
1.
Automatic Recall Timer: AUTOMATIC RECALL [A-8]:
a.) standard timing: 30 seconds
b.) variable timing: 2-30 seconds (two-second increments)
2.
No Answer Timer for station call: CALL FORWARDING-DON'T ANSWER [C-3]:
a.) standard timing: 30 seconds
b.) variable timing: 2-30 seconds (two-second increments)
3.
No Answer Timer for station call via an Attendant Console: CALL FORWARDING-DON'T
ANSWER [C-3]:
a.) standard timing: 10 seconds
b.) variable timing: 2-30 seconds (two-second increments)
4.
No Answer Timer for Call Transfer: CALL TRANSFER-ALL CALLS [C-11]:
a.) standard timing: 30 seconds
b.) variable timing: 2-30 seconds (two-second increments)
5.
Periodic Time Indication Tone Timer: PERIODIC TIME INDICATION TONE [P-11]:
a.) standard timing: first period-3 minutes; other periods-3 minutes
b.) variable timing: first period-0.5 to 12.5 minutes (0.5-minute increments), other periods-
0.5 to 12.5 minutes (0.5-minute increments)
6.
Recall Timer for unanswered paging: PAGING TRANSFER [P-10] and RADIO PAGING [R-16]:
a.) standard timing: 30 seconds
b.) variable timing: 30 to 480 seconds (30-second increments).
All other timers are variable (e.g., Register prepause timer, Sender prepause timer, and switchhook
timer).
Note:
If no data is entered, the system operates properly using Default data (RAM data). ASYD indexes are not
usually reprogrammed, with the possible exception of System Data 1, Indexes 156 and 157. All the
hexadecimal data mentioned is Default data.