S-19
General Description
This feature allows the NEAX2400 ICS to be programmed so that those features used most frequently
may be accessed by dialing a single digit.
Operating Procedure
To access a desired feature, refer to the "Operating Procedure" section of that particular "Feature
Description".
Service Conditions
1.
When accessing SINGLE-DIGIT FEATURE CODES, consideration must be given to the overall
numbering plan of the particular system, unless timing start has been provided.
2.
Timing start is not available with this feature.
Interactions
1.
For each feature with one-digit access, an entire number level is eliminated. Do not plan to have
more than one or two such features in a system.
2.
The corresponding feature cancel code does not have to be a single digit.
3.
TRUNK ANSWER ANY STATION [T-8], SPEED CALLING-SYSTEM [S-3], and DIAL ACCESS
TO THE ATTENDANT [D-2] are three applications for SINGLE-DIGIT FEATURE CODE.
4.
The digit "*" or "#" can be used as the first digit of a trunk access code and can be used as a
feature access code.