Siemens SINUMERIK 808D ADVANCED Diagnostic Manual page 89

Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

Programm
Switch control OFF - ON.
continuation:
8025
[Channel %1: ] Option '%2<OPTNX>' not set
Parameters:
%1 = Channel number
%2 = Brief description of option
Explanation:
The option for 'Advanced Surface' functionality is not set.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department.
- Purchase option
- Reset the activation of 'Advanced Surface' functionality (MD20606 $MC_PREPDYN_SMOOTHING_ON and/or MD20443
$MC_LOOKAH_FFORM)
Programm
Switch control OFF - ON.
continuation:
8027
'%1<OPTNX>' option not set
Parameters:
%1 = Brief description of option
Explanation:
The option for the 'Grinding Advanced' functionality is not set.
Reaction:
NC Start disable in this channel.
Alarm display.
Remedy:
Please contact the authorized personnel/Service.
- Buy option
- Deactivate the 'Grinding Advanced' functionality
- 'Grinding Advanced' functional scope:
Programm
Switch control OFF - ON.
continuation:
8030
[Channel %1: ] Block %2 option 'interpolation of more than %3 axes' not set
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Number of permissible axes
Explanation:
The number of axes programmed in the interpolating group exceeds the permissible number of interpolating axes.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
In the part program, program as many axes as are permitted by the configuration of the controller or enable additional
axes via option.
Programm
Clear alarm with the RESET key. Restart part program
continuation:
8031
[Channel %1: ] Block %2 axis %3: Axis has no IPO functionality
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis, spindle number
Explanation:
An axis/spindle that has been defined as a special axis/auxiliary spindle (see MD30460 $MA_BASE_FUNCTION_MASK
bit8), should be operated as an interpolating axis.
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
Cylinder error compensation
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
89

Hide quick links:

Advertisement

Table of Contents
loading