Siemens SINUMERIK 808D ADVANCED Diagnostic Manual page 188

Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Explanation:
- In calculating an arithmetic expression, an overflow has occurred (e.g. division by zero)
- In a data type, the representable value range has been exceeded
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Analyze the program and correct the defective point in the program.
Programm
Clear alarm with NC START or RESET key and continue the program.
continuation:
14055
[Channel %1: ] Block %2 impermissible NC language substitution, error code %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Error code
Explanation:
This alarm occurs in conjunction with an NC language substitution configured in MD30465 $MA_AXIS_LANG_SUB_MASK.
Error code %3 gives more detailed information about the cause of the problem:
Error code:
1: Several events had been programmed, causing the replacement cycle to be called. Only one substitution is allowed per
part program line.
2: A non-modal synchronized action had also been programmed for the part program line with the NC language substitution.
3: The system variables $P_SUB_SPOSIT and $P_SUB_SPOSMODE were called outside a replacement cycle.
Reaction:
Correction block is reorganized.
Interpreter stop
Interface signals are set.
Alarm display.
Remedy:
Modify the NC program
Programm
Clear alarm with NC START or RESET key and continue the program.
continuation:
14060
[Channel %1: ] Block %2 invalid skip level with differential block skip
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
With "Differential block skip", a skip level greater than 7 has been specified. (In packet 1 specification of a value for the
skip level is rejected by the converter as a syntax error, i.e. the only possibility is a "Suppress block" ON/OFF on one level).
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Enter a skip level (number behind the slash) less than 8.
Programm
Clear alarm with NC START or RESET key and continue the program.
continuation:
14065
[channel %1: ] block %2 error in SPRINT/ISOPRINT command: error code %4 information %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Additional information
%4 = Error code
188