SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Delete the axis addresses that have been programmed more than once.
Programm
Clear alarm with NC START or RESET key and continue the program.
continuation:
16430
[Channel %1: ] Block %2 geometry axis %3 cannot traverse as positioning axis in rotated
coordinate system
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
Explanation:
In the rotated coordinate system, traversing of a geometry axis as positioning axis (i.e. along its axis vector in the rotated
coordinate system) would mean traversing of several machine axes. This is in conflict with the positioning axis concept,
however, in which one axis interpolator runs in addition to the path interpolator!
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Traverse geometry axes as positioning axes only with rotation deactivated.
Deactivate rotation:
Keyword ROT without further specification of axis and angle.
Example: N100 ROT
Programm
Clear alarm with NC START or RESET key and continue the program.
continuation:
16440
[Channel %1: ] Block %2 rotation programmed for non-existent geometry axis
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
A rotation of a geometry axis which does not exist was programmed.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Programm
Clear alarm with NC START or RESET key and continue the program.
continuation:
16500
[Channel %1: ] Block %2 chamfer or rounding negative
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
A negative chamfer or rounding has been programmed under the keywords CHF= ..., RND=... or RNDM=...
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Values for chamfers, roundings and modal roundings must be programmed with positive values only.
Programm
Clear alarm with NC START or RESET key and continue the program.
continuation:
16510
[Channel %1: ] Block %2 no facing axis for diameter programming available
Parameters:
%1 = Channel number
%2 = Block number, label
246