Siemens SINUMERIK 808D ADVANCED Diagnostic Manual page 387

Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

61124
[Channel %1: ] Block %2: Infeed width is not programmed
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
With active simulation without tool, a value for the infeed width _MIDA must always be programmed.
Programm
Clear alarm with the RESET key. Restart part program
continuation:
61125
[Channel %1: ] Block %2: Technology selection parameter incorrectly defined
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Check technology selection parameter (_TECHNO).
Programm
Clear alarm with the RESET key. Restart part program
continuation:
61126
[Channel %1: ] Block %2: Thread length too short
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program lower spindle speed or raise reference point (reference plane).
Programm
Clear alarm with the RESET key. Restart part program
continuation:
61127
[Channel %1: ] Block %2: Wrong definition of tapping axis transformation ratio (machine data)
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Check machine data 31050 and 31060 in the appropriate gear stage of the drilling axis.
Programm
Clear alarm with the RESET key. Restart part program
continuation:
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
SINUMERIK 808D ADVANCED alarms
5.3 Cycle alarms