Siemens SINUMERIK 808D ADVANCED Diagnostic Manual page 107

Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

10703
[Channel %1: ] Channel-specific protection zone %2 violated during manual mode
Parameters:
%1 = Channel number
%2 = Protection zone number
Explanation:
The workpiece-related channel-specific protection zone has been violated. Note that another tool-related protection zone
is still active. The workpiece-related protected area can be traversed after a new NC Start.
Reaction:
Local alarm reaction.
Interface signals are set.
Alarm display.
Remedy:
Protection zone can be traversed after a new NC Start.
Programm
Alarm display showing cause of alarm disappears. No further operator action necessary.
continuation:
10704
[Channel %1: ] Block %2 protection zone monitoring is not guaranteed
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
New movements of a geometry axis which have been added could not be allowed for at the time of block preparation. It
is therefore not certain that the protection zones will not be violated. This is just a warning message without further reactions.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Take other measures to ensure that the geomotry axes motion, including the additional motion, does not violate the
protection zones. (The warning comes nevertheless) or exclude additional motions.
Programm
Alarm display showing cause of alarm disappears. No further operator action necessary.
continuation:
10706
[Channel %1: ] NCK protection zone %2 reached with axis %3 during manual mode
Parameters:
%1 = Channel number
%2 = Protection zone number
%3 = Axis name
Explanation:
The workpiece-related NCK protection zone has been reached with the specified axis. Note that another tool-related
protection zone is still active. The workpiece-related protection zone can be traversed when the PLC has issued an enable
signal.
Reaction:
Local alarm reaction.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Protection zone can be traversed after enable signal from
PLC.
Programm
Alarm display showing cause of alarm disappears. No further operator action necessary.
continuation:
10707
[Channel %1: ] Channel-specific protection zone %2 reached with axis %3 during manual mode
Parameters:
%1 = Channel number
%2 = Protection zone number
%3 = Axis name
Explanation:
The workpiece-related channel-specific protection zone has been reached with the specified axis. Note that another tool-
related protection zone is still active. The workpiece-related protection zone can be traversed when the PLC has issued
an enable signal.
Reaction:
Local alarm reaction.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Protection zone can be traversed after enable signal from
PLC.
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
107

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents