Siemens SINUMERIK 808D ADVANCED Diagnostic Manual page 429

Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

61304
[Channel %1: ] Block %2: Allowance
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Programm
Clear alarm with the RESET key. Restart part program
continuation:
61305
[Channel %1: ] Block %2: Dimension too small
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Programm
Clear alarm with the RESET key. Restart part program
continuation:
61306
[Channel %1: ] Block %2: Permissible measuring difference exceeded
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Explanation:
Remedy:
For 840D sl - up to SW 2.6 SP1 and for 828D - up to SW 4.3:
- Check setpoint value and parameter DIF
For 840D sl - as from SW 2.7 and for 828D - as from SW 4.4:
- Check setpoint value and parameter DIF
61307
[Channel %1: ] Block %2: Incorrect measuring variant %4
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Explanation:
Remedy:
For 840D sl - up to SW 2.6 SP1 and for 828D - up to SW 4.3:
- The value of parameter _MVAR is impermissible.
For 840D sl - as from SW 2.7 and for 828D - as from SW 4.4:
- The value of parameter S_MVAR is impermissible.
61308
[Channel %1: ] Block %2: Check measuring path
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
SINUMERIK 808D ADVANCED alarms
5.3 Cycle alarms
429

Hide quick links: