61416
[Channel %1: ] Block %2: Probe number is greater than the maximum number of fields
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Explanation:
Remedy:
Check parameter S_PRNUM
Measure workpiece: Parameter S_PRNUM 1 to 12
Measure tool: Parameter S_PRNUM 1 to 6
61417
[Channel %1: ] Block %2: Probe will collide with the carrier of the reference groove.
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Explanation:
Remedy:
Take up collision-free initial position of the axes involved in the measuring process.
61418
[Channel %1: ] Block %2: Protocol file too small, check MD11420: LEN_PROTOCOL_FILE.
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Explanation:
Remedy:
Check MD11420: LEN_PROTOCOL_FILE.
61419
[Channel %1: ] Block %2: Check probe calibration with reference to center of ball/circumference
of ball.
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Explanation:
Setting in MD 51740 $MNS_MEA_FUNCTION_MASK bit1 does not match calibration status in
setting data 54610 $SNS_MEA_WP_STATUS_GEN[S_PRNUM] - THOUSANDS digit: 1=circumference 0=TCP (Tool
Center Point)
Remedy:
Check machine data 51740 $MNS_MEA_FUNCTION_MASK bit1
Remedy:
1. Recalibrate probe (adjust)
2. Change probe number S_PRNUM
3. Adjust MD51740 bit1
61420
[Channel %1: ] Block %2: Check calibration of multi/mono probes.
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Explanation:
Remedy:
The workpiece probe must be calibrated according to its type and use.
61421
[Channel %1: ] Block %2: Software release of measuring cycles or NCK inadequate or set up
incorrectly - error code %4
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Explanation:
Remedy:
Causes of error: Error code see %4
A -> _OVR[] - parameter field too small. Check GUD definition.
DEF CHAN REAL _OVR[72] (up to MZ06.03.xx.xx =32)
B -> $SCS_MEA_KIN_MODE? SD55645 not set up