SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Modify part program.
Programm
Clear alarm with NC START or RESET key and continue the program.
continuation:
14756
[Channel %1: ] Block %2 motion synchronous action: %3 wrong value
Parameters:
%1 = Channel number
%2 = Block number, line number
%3 = Synact ID
Explanation:
Assignment: Illegal value.
The assignment to a variable or transfer parameter of a procedure or function was found to overshoot or undershoot the
value range.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Modify part program.
Comply with the value range of the variable or transfer parameter
Programm
Clear alarm with NC START or RESET key and continue the program.
continuation:
14757
[Channel %1: ] Block %2 motion synchronous action and wrong type
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Programmed combination between action and type of motion synchronized action is not allowed.
- RET allowed in technology cycle only
- Function "Several feeds" not allowed in technology cycle
- H and M function outputs not allowed with WHENEVER, FROM and DO
- MEASA / MEAWA / MEAC not allowed with WHENEVER, FROM and DO
- DELDTG and STOPREOF allowed only in non-modal synchronized action with WHEN and EVERY
- PRESETON / PRESETONS may only be used together with WHEN or EVERY
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Programm
Clear alarm with NC START or RESET key and continue the program.
continuation:
14758
[Channel %1: ] Block %2 programmed value not available
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The synchronous variables $AA_LOAD, $AA_TORQUE, $AA_POWER and $AA_CURR are activated by the MD36730
$MA_DRIVE_SIGNAL_TRACKING. The system variable $VA_IS: Safe actual position is only available if the MD36901
$MA_SAFE_FUNCTION_ENABLE is set and the option $ON_NUM_SAFE_AXES is set to a sufficient size.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
218
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2