Siemens SINUMERIK 808D ADVANCED Diagnostic Manual page 488

Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

SINUMERIK 808D ADVANCED alarms
5.3 Cycle alarms
61859
[Channel %1: ] Block %2: Turning has not been enabled
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Turning has not been set up on the machine.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Check machine data: 52201 $MCS_TECHNOLOGY_EXTENSION=1 (turning).
Programm
Clear alarm with the RESET key. Restart part program
continuation:
61860
[Channel %1: ] Block %2: Turning only possible on a main spindle
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
For turning, a main spindle was not selected for clamping.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Select a main spindle as clamping for turning.
Programm
Clear alarm with the RESET key. Restart part program
continuation:
61861
[Channel %1: ] Block %2: Tailstock not selected in this channel
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The tailstock was selected in another channel, but not in this channel.
The different selection/deselection results in a conflict.
When the tailstock is selected, it is not permissible that the counterspindle is positioned.
However, when the tailstock is deselected, the counterspindle should be positioned.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Select or deselect the tailstock consistently in all channels.
Programm
Clear alarm with the RESET key. Restart part program
continuation:
61862
[Channel %1: ] Block %2: It is not permissible to call a ShopTurn cycle in a ShopMill program
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
An attempt was made to call a ShopTurn cycle in a ShopMill program.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Delete block.
Programm
Clear alarm with the RESET key. Restart part program
continuation:
488
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
Diagnostics Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents