Siemens SINUMERIK 808D ADVANCED Diagnostic Manual page 298

Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Change NC program or set other mode with MD10602 $MN_FRAME_GEOAX_CHANGE_MODE.
Programm
Clear alarm with the RESET key. Restart part program
continuation:
18314
[Channel %1: ] Block %2 frame: type conflict
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
It is not possible to chain global frames and channel-specific frames. The alarm occurs if a global frame is programmed
with a channel axis name and no machine axis on this NCU is assigned to the channel axis. Channel-specific frames
cannot be programmed with machine axis names if there is no corresponding channel axis on this NCU.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Modify part program.
Programm
Clear alarm with the RESET key. Restart part program
continuation:
18400
[Channel %1: ] Block %2 language change not possible:%3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Cause
Explanation:
The selection of an external NC language is not possible due to the reason specified. The following reasons are possible
(see parameter 3):
1. Invalid machine data settings
2. Active transformation
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Remedy the specified cause of the error before selecting the language.
Programm
Clear alarm with the RESET key. Restart part program
continuation:
20000
[Channel %1: ] Axis %2 reference cam not reached
Parameters:
%1 = Channel number
%2 = Axis name, spindle number
Explanation:
After starting the reference point approach, the rising edge of the reduction cam must be reached within the section defined
in the MD34030 $MA_REFP_MAX_CAM_DIST (phase 1 of referencing). (This error occurs only with incremental encoders).
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.