Siemens SINUMERIK 808D ADVANCED Diagnostic Manual page 437

Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

Explanation:
Remedy:
For 840D sl - up to SW 2.6 SP1 and for 828D - up to SW 4.3:
- Parameter following angle (_INCA) is 0.
For 840D sl - as from SW 2.7 and for 828D - as from SW 4.4:
- Parameter following angle (alpha 1) is 0.
61348
[Channel %1: ] Block %2: Angle rel. to reference edge equals 0
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Programm
Clear alarm with the RESET key. Restart part program
continuation:
61349
[Channel %1: ] Block %2: Distance upper probe edge - measuring position = 0 for tool radius
measurement
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Explanation:
Remedy:
The distance between the upper and lower edges of the tool probe equals 0; relevant for radius measurement.
For 840D sl - up to SW 1.x: Check parameter _TP[x,9]
For 840D sl/828D - as from SW 2.5: Check setting data 54634 $SNS_MEA_TP_CAL_MEASURE_DEPTH
61350
[Channel %1: ] Block %2: Feed, speed not programmed for tool measurement with rotating spindle
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Explanation:
Remedy:
For 840D sl - up to SW 2.6 SP1 and for 828D - up to SW 4.3:
- Measuring feed and/or spindle speed during tool measurement with turning spindle not entered in GUD variable _MFS.
- Check parameter _MFS[0]
For 840D sl - as from SW 2.7 and for 828D - as from SW 4.4:
- Check parameters F1 and S1
61351
[Channel %1: ] Block %2: Tool length or radius is 0
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Explanation:
Remedy:
Cutter: - Check length and radius of the active tool in the compensation data memory
Drill: - Check length of the active tool in the compensation data memory
- Radius or tip angle of the active tool must be predefined in the compensation data memory
61352
[Channel %1: ] Block %2: Path for logfile not permitted
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Explanation:
The specified path for the log file is incorrect.
Remedy:
Check parameter _PROTNAME[0]
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
SINUMERIK 808D ADVANCED alarms
5.3 Cycle alarms
437