SINUMERIK 808D ADVANCED alarms
5.3 Cycle alarms
61120
[Channel %1: ] Block %2: Thread type inside / outside not defined
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The thread type (internal/external) was not defined.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
The internal/external thread type must be entered.
Programm
Clear alarm with the RESET key. Restart part program
continuation:
61121
[Channel %1: ] Block %2: Number of teeth per cutting edge is missing
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
No value was entered for the number of teeth per cutting edge.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Enter the number of teeth/cutting edges for the active tool into the tool list.
Programm
Clear alarm with the RESET key. Restart part program
continuation:
61122
[Channel %1: ] Block %2: Safety distance incorrectly defined in plane
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The safety clearance is negative or zero. This is not allowed.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Define the safety clearance.
Programm
Clear alarm with the RESET key. Restart part program
continuation:
61123
[Channel %1: ] Block %2: CYCLE72 cannot be simulated
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Programm
Clear alarm with the RESET key. Restart part program
continuation:
386