SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Programm
Clear alarm with the Delete key or NC START.
continuation:
16924
[Channel %1: ] Caution: program test modifies tool management data
Parameters:
%1 = Channel number
Explanation:
Tool management data is changed during program testing. It is not possible to automatically rectify the data after
termination of the program testing.
This error message prompts the user to make a backup copy of the data or to reimport the data after the operation is
terminated.
Reaction:
Alarm display.
Remedy:
Please inform the authorized personnel/service department.
Save tool data on HMI and reimport data after "ProgtestOff".
Programm
Clear alarm with the Delete key or NC START.
continuation:
16925
[Channel %1: ] Program control: action %2<ALNX> not allowed in the current state, action
%3<ALNX> active
Parameters:
%1 = Channel number
%2 = Action number/action name
%3 = Action number/action name
Explanation:
The action has been refused since a mode or sub-mode change (change to automatic mode, MDI, JOG, overstoring,
digitizing, etc.) is taking place.
Example: This alarm message is output if the Start key is pressed during a mode or sub-mode change from, for example,
automatic to MDI, before the NCK has confirmed selection of the mode.
Reaction:
Alarm display.
Remedy:
Repeat action.
Programm
Clear alarm with the Delete key or NC START.
continuation:
16927
[Channel %1: ] Action %2<ALNX> at active interrupt treatment not allowed
Parameters:
%1 = Channel number
%2 = Action number/action name
Explanation:
This action may not be activated during interrupt processing (e.g. mode change).
Reaction:
Alarm display.
Remedy:
Reset or wait until interrupt processing is terminated.
Programm
Clear alarm with the Delete key or NC START.
continuation:
16928
[Channel %1: ] Interrupt treatment: action %2<ALNX> not possible
Parameters:
%1 = Channel number
%2 = Action number/action name