61863
[Channel %1: ] Block %2: It is not permissible to call a ShopMill cycle in a ShopTurn program
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
An attempt was made to call a ShopMill cycle in a ShopTurn program.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Delete block.
Programm
Clear alarm with the RESET key. Restart part program
continuation:
61864
[Channel %1: ] Block %2: The selection, tailstock yes/no must be identical in all channels
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The selection, tailstock yes/no in the program header must be identical in all channels.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
For tailstock yes/no in the program header, make the same selection for all channels.
Programm
Clear alarm with the RESET key. Restart part program
continuation:
61865
[Channel %1: ] Block %2: Calling a ShopTurn cycle is only permissible in a ShopTurn program
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
It is not permissible that a ShopTurn cycle is used outside a ShopTurn program, as the required environment variables
are otherwise not assigned.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Calling a ShopTurn cycle in a ShopTurn program. If this is not possible, then the task must be programmed using G code.
Programm
Clear alarm with the RESET key. Restart part program
continuation:
61866
[Channel %1: ] Block %2: It is only permissible to call a ShopMill cycle in a ShopMill program
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
It is not permissible that a ShopMill cycle is used outside a ShopMill program, as the required environment variables are
otherwise not assigned.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Calling a ShopMill cycle in a ShopMill program. If this is not possible, then the task must be programmed using G code.
Programm
Clear alarm with the RESET key. Restart part program
continuation:
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
SINUMERIK 808D ADVANCED alarms
5.3 Cycle alarms