5.2 NCK alarms
4341
[Channel %1: ] Block %2 no data set available for transformation no. %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Transformation number
Explanation:
Only a limited number of machine data sets (usually 2) is available for each related group of transformations (e.g. orientation
transformations, Transmit, Tracyl, etc.). This alarm is output if an attempt is made to set more transformations from a group.
Example:
Two orientation transformations are allowed. The machine data contains e.g.:
TRAFO_TYPE_1 = 16 ; 1st orientation transformation
TRAFO_TYPE_2 = 33 ; 2nd orientation transformation
TRAFO_TYPE_3 = 256 ; 1st transmit transformation
TRAFO_TYPE_4 = 20 ; 3rd orientation transformation ==> This entry triggers alarm
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Enter valid machine data.
Programm
Clear alarm with the RESET key. Restart part program
continuation:
4342
[Channel %1: ] Invalid machine data for general 5-axis transformation error no. %2
Parameters:
%1 = Channel number
%2 = Error type
Explanation:
The machine data which describe the axis directions and the basic orientation and the input axes for the general 5-axis
transformation are invalid. The error parameter displayed specifies the cause of the alarm:
- 1: The first axis (MD2.... $MC_TRAFO5_AXIS1_...) is not defined (all three entries of the vector are 0)
- 2: The second axis (MD2.... $MC_TRAFO5_AXIS2_...) is not defined (all three entries of the vector are 0)
- 3: The basic orientation (MD2.... $MC_TRAFO5_BASE_ORIENT_...) is not defined (all three entries of the vector are 0)
- 4: The first and second axis are (virtually) parallel
- 5: On MD2.... $MC_TRAFO_TYPE_ = 56 (rotatable tool and workpiece) there is no 4-axis transformation, i.e. 2 rotary
axes must always be available. (See MD2.... $MC_TRAFO_AXES_IN_...)
- 6: The third axis (MD2.... TRAFO5$MC_TRAFO5_AXIS3_...) is not defined (all three entries of the vector are 0) (6-axis
transformation)
- 7: The normal tool vector (MD2.... TRAFO6$MC_TRAFO6_BASE_ORIENT_NORMAL_...) is not defined (all three entries
of the vector are 0) (6-axis transformation)
- 8: The basic tool orientation (MD2.... $MC_TRAFO5_BASE_ORIENT_...) and the normal tool vector (MD2....
$MC_TRAFO6_BASE_ORIENT_NORMAL_...) are (virtually) parallel (6-axis transformation)
- 9: The first external axis (MD2.... $MC_TRAFO7_EXT_AXIS1_*) has not been defined (all three vector entries are 0) (7-
axis transformation)
-10: Invalid transformation type (MD2.... $MC_TRAFO_TYPE_...). A transformation type unequal to 24 has been entered
for the generic 7-axis transformation.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Set valid machine data.
Programm
Clear alarm with the RESET key. Restart part program
continuation:
4343
[Channel %1: ] Attempt made to change the machine data of an active transformation.
Parameters:
%1 = Channel number