SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
15500
[Channel %1: ] Block %2 illegal angle of shear
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The function CSHEAR has been called with an illegal (impossible) angle of shear, e.g. when the sum of angles between
the axis vectors is greater than 360 degrees.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program the angle of shear in accordance with the geometrical conditions of the machine and workpiece system.
Programm
Clear alarm with the RESET key. Restart part program
continuation:
15700
[Channel %1: ] Block %2 illegal cycle alarm number %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Cycle alarm number
Explanation:
A SETAL command has been programmed with a cycle alarm number smaller than 60 000 or greater than 69 999.
Alarm reaction of Siemens standard cycles:
Nos. 61 000 -61 999: Interpreter stop; delete with Reset
Nos. 62 000 - 62 999: Compensation block; delete with NC Start
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program alarm number in the SETAL instruction in the correct range.
Programm
Clear alarm with the RESET key. Restart part program
continuation:
15701
[Channel %1: ] Block %2 motion synchronous action: %3 illegal cycle alarm number %4
Parameters:
%1 = Channel number
%2 = Block number, line number
%3 = Synact ID
%4 = Cycle alarm number
Explanation:
A SETAL command has been programmed with a cycle alarm number smaller than 60 000 or greater than 69 999.
Alarm reaction of Siemens standard cycles:
Nos. 61 000 -61 999: Interpreter stop; delete with Reset
Nos. 62 000 - 62 999: Compensation block; delete with NC Start
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Program alarm number in the SETAL instruction in the correct range.
Programm
Clear alarm with the RESET key. Restart part program
continuation:
15800
[Channel %1: ] Block %2 wrong starting conditions for CONTPRON/CONTDCON
Parameters:
%1 = Channel number
%2 = Block number, label
238