SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Remedy:
Deselect transformation before writing into the axial data (keyword: TRAFOOF) or use the machine axis names as axis
index.
Programm
Clear alarm with NC START or RESET key and continue the program.
continuation:
17050
[Channel %1: ] Block %2 illegal value
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
A value has been programmed that exceeds the value range or a limit value of a variable or a machine data item.
For example: In a string variable (e.g. GUD or LUD), a string needs to be written that exceeds the agreed string length in
the variable definition.
- If an illegal value is to be written to a tool or magazine management variable (e.g. illegal cutting edge number in
$TC_DPCE[x,y] or illegal magazine location number in $TC_MDP2[x,y])
- The value of MTL is incorrect. MTL must be programmed with a multitool location number of a multitool that is
programmed in the command T=magazine location number in the same NC block.
- An illegal value is to be written in $P_USEKT or $A_DPB_OUT[x,y]
- An illegal value is to be written in a machine data (e.g. MD10010 $MN_ASSIGN_CHAN_TO_MODE_GROUP[0] = 0)
- On accessing an individual frame element, a frame component other than TRANS, ROT, SCALE or MIRROR was
addressed or the CSCALE function was assigned a negative scale factor.
A multitool number has been programmed that collides with a previously defined T number or a previously defined
magazine number.
When programming DELMLOWNER: The command cannot be programmed with the T number of a tool that is part of a
multitool.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Address frame components only with the keywords provided; program the scale factor between the limits of 0.000 01 to
999.999 99.
Programm
Clear alarm with the RESET key. Restart part program
continuation:
17055
[Channel %1: ] Block %2 GUD variable not existing
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The required GUD variable was not found for a MEACALC procedure during read or write access.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Check whether all the GUDs were created for MEACALC.
DEF CHAN INT _MVAR, _OVI[11]
DEF CHAN REAL _OVR[32], _EV[20], _MV[20], _SPEED[4], _SM_R[10], _ISP[3]
DEF NCK REAL _TP[3,10], _WP[3,11], _KB[3,7], _CM[8], _MFS[6]
DEF NCK BOOL _CBIT[16]
DEF NCK INT _CVAL[4].
Programm
Clear alarm with the RESET key. Restart part program
continuation:
17060
[Channel %1: ] Block %2 requested data area too large
Parameters:
%1 = Channel number
%2 = Block number, label
274