Siemens SINUMERIK 808D ADVANCED Diagnostic Manual page 423

Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

61279
[Channel %1: ] Block %2: If tool angle equals 90°, both tool diameters must be equal
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
For tool angles equal to 90°, the two tool diameters must be identical.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Correct the tool angle or the tool diameters.
Programm
Clear alarm with the RESET key. Restart part program
continuation:
61280
[Channel %1: ] Block %2: %4- Mirroring missing in work offset for counterspindle
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The work offset for counterspindle machining does not have Z mirroring.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Select Z mirroring for the work offset used.
Programm
Clear alarm with the RESET key. Restart part program
continuation:
61281
[Channel %1: ] Block %2: starting point of machining outside retraction planes
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The starting point of machining is outside the retraction planes.
It is derived from the programmed geometry plus the safety distance in the selected machining direction.
The calculated point must lie within the retraction area to ensure safe approach.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Adjust the retraction planes.
Programm
Clear alarm with the RESET key. Restart part program
continuation:
61282
[Channel %1: ] Block %2: end point of machining outside retraction planes
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The end point of machining is outside the retraction planes.
It is calculated internally (according to the selected machining strategy).
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Adjust the retraction planes.
Programm
Clear alarm with the RESET key. Restart part program
continuation:
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
SINUMERIK 808D ADVANCED alarms
5.3 Cycle alarms
423

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents