Siemens SINUMERIK 808D ADVANCED Diagnostic Manual page 177

Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

Explanation:
The selected program %2 in channel%1 cannot be executed because the channel-specific start disable is set for this
channel.
Background: When ShopMill or ShopTurn programs are selected or changed, the HMI performs a consistency check of
the parameters that have been entered. During this time, the processing of the selected NC program is inhibited by the
HMI setting what is known as the "channel-specific start disable". If an NC start is now rejected because of a set channel-
specific start disable, then alarm 14004 is output as a function of MD 11411 $MN_ENABLE_ALARM_MASK bit 15. The
alarm is also output in the event of a block search, but in this case it is not dependent on MD 11411
$MN_ENABLE_ALARM_MASK bit 15.
Reaction:
Alarm display.
Remedy:
Repeat NC start
Programm
Clear alarm with the Delete key or NC START.
continuation:
14005
[Channel %1: ] Block %2 program %3 program-specific start disable has been set
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Program name
Explanation:
Program %3 cannot be executed, because the program-specific start disable has been set for this file.
Background: When an editing operation for a ShopMill or ShopTurn program has been completed, the HMI performs a
consistency check of the parameters that have been entered. During this time, CNC program processing is inhibited by
setting what is known as the "program-specific start disable" by the HMI. If NC start is pressed during the test, the start is
not executed, and alarm 14005 is output as a function of MD 11411 $MN_ENABLE_ALARM_MASK bit 6.
Alarm 14005 is also output if the part program processing encounters a subroutine for which the file attribute "start disable"
is set.
After the test step has been completed, the program processing can continue by pressing NC start.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Repeat NC start
Programm
Clear alarm with NC START or RESET key and continue the program.
continuation:
14006
[Channel %1: ] Block %2 invalid program name %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Program name
Explanation:
When selecting or calling an NC program it was found that the program name did not follow NC conventions:
- The length of the program name, without prefix _N_ and Suffix _MPF / _SPF, must not exceed 24 characters, as otherwise
the program name is truncated in the OPI variables.
Reaction:
Alarm display.
Remedy:
- Shorten the name of the program.
- Suppress the alarm with MD 11415 $MN_SUPPRESS_ALARM_MASK_2 bit 9.
Programm
Clear alarm with the Delete key or NC START.
continuation:
14007
[Channel %1: ] Block %2 Program %3 is being edited
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Program name
Explanation:
Program %3 cannot be executed because it has been disabled by another application, for example the HMI Editor.
Background: Program %3 is on an external data carrier (CF card, network drive, USB device), and should be executed
from there in EES mode (Execution from External Storage). But the program cannot be processed because it has been
opened for writing by another application, for example the HMI Editor, and the WRITE lock has been set for this file.
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
177

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents