SINUMERIK 808D ADVANCED alarms
5.3 Cycle alarms
61330
[Channel %1: ] Block %2: Coordinate rotation active
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
No measuring possible in the rotated coordinate system.
Remedy:
Check the conditions for measuring.
61331
[Channel %1: ] Block %2: Angle too large, change measuring axis
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Remedy:
For 840D sl - up to SW 2.6 SP1 and for 828D - up to SW 4.3:
- Parameter starting angle (_STA) is too large for the measuring axis specified.
For 840D sl - as from SW 2.7 and for 828D - as from SW 4.4:
- Parameter starting angle (alpha 0) is too large for the measuring axis specified.
Select another measuring axis.
61332
[Channel %1: ] Block %2: Modify tool tip position
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The tool tip is below the measuring probe surface (e.g. for a ring gauge or cube).
Remedy:
Place the tool above the measuring probe surface.
61333
[Channel %1: ] Block %2: Check calibration block number
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Remedy:
Parameter _CALNUM is too large, reduce it to a permissible value
For 840D sl - up to SW 1.x:
- Increase the maximum value of _CVAL[2] in GUD6
For 840D sl/828D - as from SW 2.5:
- Check following machine data: 51601 $MNS_MEA_CAL_EDGE_NUM
61334
[Channel %1: ] Block %2: Check safety area
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Remedy:
Check the parameters for the protection zone
For 840Dsl - up to SW 2.6 SP1 and for 828D - up to SW 4.3:
-_SZA or _SZO
For 840D sl - as from SW 2.7 and for 828D - as from SW 4.4:
- XS, YS or ZS
61335
[Channel %1: ] Block %2: Reserved
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Alarm triggered: Reserved
Remedy:
reserved