SINUMERIK 808D ADVANCED alarms
5.4 Drive alarms
Programm
Switch control OFF - ON.
continuation:
380500
PROFIBUS/PROFINET: Fault on drive %1, code %2, value %3, time %4
Parameters:
%1 = Axis
%2 = Fault code of drive (P947(/945)/P824)
%3 = Fault value of drive ((P949/P826)
%4 = Fault time of drive (P948/P825)
Explanation:
Contents of fault memory of assigned drive.
Reaction:
Alarm display.
Remedy:
See drive documentation for fault codes/fault values.
Programm
Alarm display showing cause of alarm disappears. No further operator action necessary.
continuation:
380501
PROFIBUS/PROFINET: Fault on bus, slave/device, DO ID %1, code %2, value %3, time %4
Parameters:
%1 = 8 bit bus number, 8 bit slave/device number, 16 bit DO ID
%2 = Fault code of drive (P947)
%3 = Fault value of the drive (P949)
%4 = Fault time of the drive (P948)
Explanation:
Contents of the fault memory of the assigned slave/device.
Reaction:
Alarm display.
Remedy:
See drive documentation for fault codes/fault values.
Programm
Alarm display showing cause of alarm disappears. No further operator action necessary.
continuation:
380502
PROFIBUS/PROFINET: Bus %1, slave/device %2 configuration changed
Parameters:
%1 = Bus number
%2 = Slave/device address
Explanation:
The bus configuration has changed.
Causes:
- First commissioning
- New slave/device recognized on the bus
Reaction:
Interface signals are set.
Alarm display.
Remedy:
In order to operate the bus with the new configuration, an additional restart will be required.
Programm
Switch control OFF - ON.
continuation:
380503
PROFIBUS/PROFINET: Bus %1 configuration changed
Parameters:
%1 = Bus number
Explanation:
A new SDB with a modified configuration has been provided.
The new settings will be activated only at the next bus power up.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
In order to operate the bus with the new configuration, an additional restart will be required.
Programm
Switch control OFF - ON.
continuation:
520
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
Diagnostics Manual