Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
The program must be canceled with Reset.
Programm
Clear alarm with the RESET key. Restart part program
continuation:
16935
[Channel %1: ] Action %2<ALNX> not possible due to search run
Parameters:
%1 = Channel number
%2 = Action number/action name
Explanation:
The action is not allowed as block search is currently running via program test. Block search via program test: "PI Service
_N_FINDBL with mode parameter 5.
With this block search type, it is not permissible to activate program test or dry run feedrate.
Reaction:
Alarm display.
Remedy:
Activate the action after block search is terminated.
Programm
Clear alarm with the Delete key or NC START.
continuation:
16936
[Channel %1: ] Action %2<ALNX> not possible due to active dry run
Parameters:
%1 = Channel number
%2 = Action number/action name
Explanation:
This action is not allowed as dry run feedrate is currently active.
Example: It is not permissible to activate block search via program test (PI service _N_FINDBL with mode parameter 5)
when dry run feedrate is active.
Reaction:
Alarm display.
Remedy:
Cancel program with the RESET key.
Programm
Clear alarm with the Delete key or NC START.
continuation:
16937
[Channel %1: ] Action %2<ALNX> not possible due to program test
Parameters:
%1 = Channel number
%2 = Action number/action name
Explanation:
This action is not allowed as program test is currently active.
Example: It is not permissible to activate block search via program test (PI service _N_FINDBL with mode parameter 5)
when program test is active.
Reaction:
Alarm display.
Remedy:
Deactivate program test.
Programm
Clear alarm with the Delete key or NC START.
continuation:
16938
[Channel %1: ] Action %2<ALNX> canceled due to active gear change
Parameters:
%1 = Channel number
%2 = Action number/action name
Explanation:
Reorganization events are, among others, subprogram cancelation, delete distance-to- go and interrupts, axis exchange,
exiting the correction state. These events wait for the end of a gear change. However, the maximum waiting period has
elapsed.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.