Siemens SINUMERIK 808D ADVANCED Diagnostic Manual page 237

Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

Remedy:
Please inform the authorized personnel/service department.
Check whether the selected INI block is contained in the file system of the NCK. The present protection level must be
selected to be at least equal to (or greater than) the protection level that has been defined for the read, write or execution
function at the time of creating the file.
Programm
Clear alarm with the RESET key. Restart part program
continuation:
15410
[Channel %1: ] Block %2 initialization file contains invalid M function
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The only M function allowed in an Init block is the M02, M17 or M30 end-of-program function.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Remove all M functions from the Init block except for the end identifier.
An Init block may contain value assignments only (and global data definitions if they are not defined again in a program
that can be executed later) but no motion or synchronous actions.
Programm
Clear alarm with the RESET key. Restart part program
continuation:
15420
[Channel %1: ] Block %2 instruction in current mode not allowed
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The alarm is output in the following situations:
- The interpreter has detected an illegal instruction (e.g. a motion command) while processing an INI file or a definition file
(macro or GUD).
- In a GUD file, the access security for a machine data item is to be changed with REDEF, although
an ACCESS file (_N_SACCESS_DEF, _N_MACCESS_DEF, _N_UACCESS_DEF) is available.
Access rights for machine data can then only be changed via one of the ACCESS files with REDEF.
- When processing the safety initialization program /_N_CST_DIR/_N_SAFE_SPF an illegal instruction was detected due
to the reduced language scope configured.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
- Correct the INI, GUD or macro file.
- Correct part program.
Programm
Clear alarm with NC START or RESET key and continue the program.
continuation:
15460
[Channel %1: ] Block %2 syntax error when locking
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The addresses programmed in the block are not compatible with the modal syntax-determining G function.
Example:
N100 G01 ... I .. J.. K.. LF
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Correct the displayed block and ensure that the G functions and addresses in the block are in agreement.
Programm
Clear alarm with NC START or RESET key and continue the program.
continuation:
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
237

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents