SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Remedy:
Error ID:
- 30XX => assign all gantry axes to the current channel, for example via axis exchange.
- 40XX => set all axes of the gantry group to the same axis state, for example assign all axes to the NC program, or assign
all axes to the PLC.
- 50XX => make all gantry axes known to the required channel.
- 60XX => make all gantry axes known to the required channel.
:end
Programm
Clear alarm with the RESET key. Restart part program
continuation:
10700
[Channel %1: ] Block %2 NCK protection zone %3 violated during automatic or MDI mode
Parameters:
%1 = Channel number
%2 = Block number
%3 = Protection zone number
Explanation:
The workpiece-related NCK protection zone has been violated. Note that another tool-related protection zone is still active.
The workpiece-related protected area can be traversed after a new NC Start.
Reaction:
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm.
The SHOWALARM and SETVDI reactions can be suppressed with MD11415 $MN_SUPPRESS_ALARM_MASK_2 bit20.
Remedy:
Protection zone can be traversed after a new NC Start.
Programm
Clear alarm with NC START or RESET key and continue the program.
continuation:
10701
[Channel %1: ] Block %2 channel-specific protection zone %3 violated during automatic or MDI
mode
Parameters:
%1 = Channel number
%2 = Block number
%3 = Protection zone number
Explanation:
The workpiece-related channel-specific protection zone has been violated. Note that another tool-related protection zone
is still active. The workpiece-related protected area can be traversed after a new NC Start.
Reaction:
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm.
The SHOWALARM and SETVDI reactions can be suppressed with MD11415 $MN_SUPPRESS_ALARM_MASK_2 bit20.
Remedy:
Protection zone can be traversed after a new NC Start.
Programm
Clear alarm with NC START or RESET key and continue the program.
continuation:
10702
[Channel %1: ] NCK protection zone %2 violated during manual mode
Parameters:
%1 = Channel number
%2 = Protection zone number
Explanation:
The workpiece-related NCK protection zone has been violated. Note that another tool-related protection zone is still active.
The workpiece-related protected area can be traversed after a new NC Start.
Reaction:
Local alarm reaction.
Interface signals are set.
Alarm display.
Remedy:
Protection zone can be traversed after a new NC Start.
Programm
Alarm display showing cause of alarm disappears. No further operator action necessary.
continuation:
106
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2