SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Explanation:
The specified program has been searched to the end of the program without the selected search target having been found.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Check the part program, change the block search (typing error in the part program) and restart the search.
Programm
Clear alarm with the RESET key. Restart part program
continuation:
15360
[Channel %1: ] Illegal target of block search (syntax error)
Parameters:
%1 = Channel number
Explanation:
The specified search target (block number, label or string) is not allowed in block search.
Reaction:
Alarm display.
Remedy:
Correct target of block search.
Programm
Clear alarm with the Delete key or NC START.
continuation:
15370
[Channel %1: ] Target of block search not found
Parameters:
%1 = Channel number
Explanation:
In a block search, an impermissible search target has been specified (e.g. negative block number).
Reaction:
Alarm display.
Remedy:
Check the specified block number, label or character string. Repeat entry with correct search target.
Programm
Clear alarm with the Delete key or NC START.
continuation:
15380
[Channel %1: ] Block %2 illegal incremental programming in axis %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis
Explanation:
The first axis programming after "search to block end point" is performed incrementally. This is not allowed in the following
situations:
- After searching the target a transformation change has taken place.
- A frame with rotation component is active. The programmed axis is involved in the rotation.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Find search destination in which the axes are programmed using an absolute reference.
Deactivate adding of the accumulated search position with SD42444 $SC_TARGET_BLOCK_INCR_PROG = FALSE.
Use search run with calculation "at contour".
Programm
Clear alarm with the RESET key. Restart part program
continuation:
15400
[Channel %1: ] Block %2 selected initial INIT block does not exist
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The operator has selected an INI block for a read, write or execution function which:
1. Does not exist in the NCK range or
2. Does not have the necessary protection level required for performing the function.
Reaction:
Alarm display.