Siemens SINUMERIK 808D ADVANCED Diagnostic Manual page 275

Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

Explanation:
The maximum memory space of 8 KB available for a symbol has been exceeded.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Reduce array dimensions.
Programm
Clear alarm with NC START or RESET key and continue the program.
continuation:
17070
[Channel %1: ] Block %2 data is write-protected
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
An attempt was made to write into a write-protected variable (e.g. a system variable). Safety Integrated: Safety system
variables can only be written into via the safety SPL program.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Modify part program.
Safety Integrated:
- Delete write accesses to safety system variables in part programs other than the safety SPL program
- Verify the release of the safety functionality
Programm
Clear alarm with NC START or RESET key and continue the program.
continuation:
17071
[Channel %1: ] Block %2 data read-protected
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
An attempt has been made to read a read-protected variable (e.g. a system variable).
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Please set the corresponding access right or modify the part program.
Programm
Clear alarm with NC START or RESET key and continue the program.
continuation:
17080
[Channel %1: ] Block %2 %3 value below lower limit
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = MD
Explanation:
An attempt was made to write into a machine data with a value smaller than the defined lower limit.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Determine the input limits of the machine data and assign a
value within these limits.
Programm
Clear alarm with NC START or RESET key and continue the program.
continuation:
17090
[Channel %1: ] Block %2 %3 value exceeds upper limit
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = MD
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
275

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents