Siemens SINUMERIK 808D ADVANCED Diagnostic Manual page 164

Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
12554
[Channel %1: ] Block %2 replacement cycle %3 for the predefined procedure is missing.
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Cycle name
Explanation:
The replacement cycle that is to be called instead of the predefined procedure
is not present / unknown in the control.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Press the NC stop key and select the "Compensation block" function by pressing the PROGRAM CORRECT softkey. The
cursor will position itself in the faulty block.
- Correct the name used for the predefined procedure (write error)
- Or load the replacement cycle into one of the cycle directories (+ restart)
- Or set the machine data bit for the predefined procedure in MD11754 $MN_COUPLE_CYCLE_MASK to 0 so that the
predefined procedure is executed again.
Programm
Clear alarm with NC START or RESET key and continue the program.
continuation:
12555
[Channel %1: ] Block %2 function not available (identifier %3)
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Fine ID
Explanation:
The identifier is not available for this system.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Press the NC stop key and select the "Compensation block" function by pressing the "Program correct" softkey. The
correction indicator will position in the incorrect block.
- Correct the name used (write error)
- Use a better software system in case of malfunction
- Check the definition of variables, subroutines and macros
- Declare a subroutine with EXTERNAL; load the subroutine to SPF-Dir
- Check the interface definition of the subroutine
Programm
Clear alarm with NC START or RESET key and continue the program.
continuation:
12556
[Channel %1: ] Block %2 name %3 Name is already known
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Source symbol
Explanation:
The name of the symbol to be created is part of the NC language scope and therefore already known. Although the NC
function is not active, this name can no longer be used for GUDs, macros and PROC definitions.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Press key NC Stop and select "Correction block" function by pressing softkey "Program correct". The correction indicator
is set to the incorrect block.
- Correct the name used (typing error)
- With MD10711 $MN_NC_LANGUAGE_CONFIGURATION = 2 or 4, only those language commands are created, the
option of which has been set
or the function of which is active.
164
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
Diagnostics Manual

Hide quick links:

Advertisement

Table of Contents
loading