Explanation:
There is an error in the definition of the protection zone. The error number gives the specific reason for the alarm:
No.
Meaning
1:
Incomplete or conflicting contour definition.
2:
Contour encompasses more than one surface area.
3:
Tool-related protection zone is not convex.
4:
If both boundaries are active in the 3rd dimension of the protection zone and both limits have the same value.
5:
The number of the protection zone does not exist (negative number, zero or greater than the maximum number of
protection zones).
6:
Protection zone definition consists of more than 10 contour elements.
7:
Tool-related protection zone is defined as inside protection zone.
8:
Incorrect parameter used.
9:
Protection zone to be activated is not defined.
10:
Incorrect modal G code used for protection zone definition.
11:
Contour definition incorrect or frame activated.
12:
Other, not further specified errors.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Modify definition of the protection zone and check MD.
Programm
Clear alarm with NC START or RESET key and continue the program.
continuation:
18001
[Channel %1: ] Block %2 channel-specific protection zone %3 incorrect. Error code %4
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Number of the channel-specific protection zone
%4 = Error specification
Explanation:
There is an error in the definition of the protection zone. The error number gives the specific reason for the alarm.
No.
Meaning
1:
Incomplete or conflicting contour definition.
2:
Contour encompasses more than one surface area.
3:
Tool-related protection zone is not convex.
4:
If both boundaries are active in the 3rd dimension of the protection zone and both limits have the same value.
5:
The number of the protection zone does not exist (negative number, zero or greater than the maximum number of
protection zones).
6:
Protection zone definition consists of more than 10 contour elements.
7:
Tool-related protection zone is defined as inside protection zone.
8:
Incorrect parameter used.
9:
Protection zone to be activated is not defined.
10:
Incorrect modal G code used for protection zone definition.
11:
Contour definition incorrect or frame activated.
12:
Other, not further specified errors.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Modify definition of the protection zone and check MD.
Programm
Clear alarm with NC START or RESET key and continue the program.
continuation:
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
293