SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Remedy:
Modify part program. Synchronize preprocessing run and main run.
Programm
Clear alarm with the Delete key or NC START.
continuation:
14404
[Channel %1: ] Block %2 illegal parameterization of transformation
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Error has occurred when selecting transformation.
Possible causes of error:
- An axis traversed by the transformation has not been enabled:
- is being used by another channel (-> enable)
- is in spindle mode (-> enable with SPOS)
- is in POSA mode (-> enable with WAITP)
- is concurrent Pos axis (-> enable with WAITP)
- Parameterization via machine data has an error
- Axis or geometry axis assignment to the transformation has an error,
- Machine data has an error (-> modify machine data, restart)
Please note: Any axes not enabled might be signaled via alarm 14092 or alarm 1011 instead of alarm 14404.
Transformation-dependent error causes can be in: TRAORI: -
TRANSMIT:
- The current machine axis position is unsuitable for selection (e.g. selection in the pole) (-> change position slightly).
- Parameterization via machine data has an error.
- Special requirement with respect to the machine axis has not been fulfilled (e.g. rotary axis is not a modulo axis) (->
modify machine data, restart).
TRACYL:
The programmed parameter is not allowed when transformation is selected.
TRAANG:
- The programmed parameter is not allowed when transformation is selected.
- Parameterization via machine data has an error.
- Parameter is faulty (e.g. TRAANG: unfavorable angle value (-> modify machine data, restart)
Persistent transformation:
- Machine data for persistent transformation are wrong (-> consider dependencies, change machine data, restart)
Only with active "OEM transformation" compile cycle:
The axes included in the transformation must be referenced.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Modify part program or machine data.
Only with active "OEM transformation" compile cycle:
Reference the axes included in the transformation before selecting transformation.
Programm
Clear alarm with NC START or RESET key and continue the program.
continuation:
14410
[Channel %1: ] Block %2 spline active at geometry axis changeover
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
It is not allowed to change the assignment of geometry axes to channel axes in a spline curve definition.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.