Siemens SINUMERIK 808D ADVANCED Diagnostic Manual page 277

Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

17120
[Channel %1: ] Block %2 analog input no. %3 not activated
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Input number
Explanation:
An attempt has been made by means of the system variable $A_INA[n] to read an analog input n that has not been activated
by the MD10300 $MN_FASTIO_ANA_NUM_INPUTS.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Modify part program or machine data accordingly.
Programm
Clear alarm with NC START or RESET key and continue the program.
continuation:
17130
[Channel %1: ] Block %2 analog output no. %3 not activated
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = No. of output
Explanation:
An attempt has been made by means of the system variable $A_OUTA[n] to write or read an analog output n that has not
been activated by the MD10310 $MN_FASTIO_ANA_NUM_OUTPUTS.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Modify part program or machine data accordingly.
Programm
Clear alarm with NC START or RESET key and continue the program.
continuation:
17140
[Channel %1: ] Block %2 NCK output %3 is assigned to a function via machine data
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = No. of output
Explanation:
The programmed digital/analog output is assigned to an NC function (e.g. software cams).
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Use another output or deactivate concurrent NC function via
MD.
Programm
Clear alarm with NC START or RESET key and continue the program.
continuation:
17150
[Channel %1: ] Block %2 maximum of %3 NCK outputs programmable in the block
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Quantity
Explanation:
No more than the specified number of outputs may be programmed in an NC block.
The quantity of hardware outputs is defined in the MDs:
MD10360 $MN_FASTIO_DIG_NUM_OUTPUTS and
MD10310 $MN_FASTIO_ANA_NUM_OUTPUTS
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
277