Siemens SINUMERIK 808D ADVANCED Diagnostic Manual page 383

Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Modify drilling depth.
Programm
Clear alarm with the RESET key. Restart part program
continuation:
61108
[Channel %1: ] Block %2: Illegal values for radius and insertion depth parameters
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The radius (_RAD1) and insertion depth (_DP1) parameters for defining the helix path for the depth infeed have been
incorrectly specified.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Modify parameter.
Programm
Clear alarm with the RESET key. Restart part program
continuation:
61109
%[[Channel %1: ] Block %2: %]Milling direction parameter incorrectly defined
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The value of the parameter for the cutting direction _CDIR has been incorrectly defined.
Remedy:
- Change milling direction.
- During pocket machining (CYCLE63), the selected milling direction must match the milling direction of centering/rough
drilling.
Programm
Clear alarm with the RESET key. Restart part program
continuation:
61110
[Channel %1: ] Block %2: Finishing allowance at the base is greater than the depth infeed
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The finishing allowance at the base has been specified greater than the maximum depth infeed.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Either reduce finishing allowance or increase depth infeed.
Programm
Clear alarm with the RESET key. Restart part program
continuation:
61111
[Channel %1: ] Block %2: Infeed width is greater than the tool diameter
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The programmed infeed width is greater than the diameter of the active tool.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
SINUMERIK 808D ADVANCED alarms
5.3 Cycle alarms