Siemens SINUMERIK 808D ADVANCED Diagnostic Manual page 508

Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

SINUMERIK 808D ADVANCED alarms
5.3 Cycle alarms
62319
[Channel %1: ] Block %2: No internal correction of the calibration data
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Explanation:
Remedy:
Check probe alignment/spindle position!
The alignment (programmed position) of the tool probe in the workspindle must be identical during calibration
and measuring!
If these positions vary, the calibration data cannot be corrected cycle-internally with regards to a coordinate
rotation of the workplane around the infeed axis!
62320
[Channel %1: ] Block %2 Individual edges lie outside the dimensional difference: %4
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Explanation:
Remedy:
Measurement of the individual edges shows that the specified number of edges lies outside the dimensional difference.
A decision has to be made: whether or not one can continue working with this tool.
62321
[Channel %1: ] Block %2: Rotary axis 1: Diameter tolerance of calibration ball between
measurement %4 exceeded
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Explanation:
see measured diameter in the parameters _OVR[75] to _OVR[77] or the value in SD $SCS_MEA_KIN_DM_TOL
Remedy:
Check the calibration data or recalibrate the 3D probe
Check the mechanical structure of the calibration ball in the machine
62322
[Channel %1: ] Block %2: Rotary axis 2: Diameter tolerance of calibration ball between
measurement %4 exceeded
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Explanation:
see measured diameter in the parameters _OVR[75] to _OVR[77] or the value in SD $SCS_MEA_KIN_DM_TOL
Remedy:
Check the calibration data or recalibrate the 3D probe
Check the mechanical structure of the calibration ball in the machine
62377
[Channel %1: ] Block %2: Dimensional tolerance %4 exceeded
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Explanation:
Remedy:
62500
[Channel %1: ] Block %2: GWPS has been limited
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Explanation:
Remedy:
Check limit value for GWPS and program a lower value in the NC program if necessary
Programm
Clear alarm with the Delete key or NC START.
continuation: