Siemens SINUMERIK 808D ADVANCED Diagnostic Manual page 532

Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

System responses
6.2 Cancel criteria for alarms
6.2
Cancel criteria for alarms
Identifier
CANCELCLEAR
Effects
The alarm is cleared in any channel when the Cancel key is pressed. It is also cleared by the Start part
program key.
● Clear the alarm with the "ALARM CANCEL" key or with the "CYCLE START" key.
Identifier
CLEARHIMSELF
Effects
Self-clearing alarm. The alarm is not cleared by an operator action but explicitly by a "clearAlarm"
programmed in the NCK source code.
● The alarm is no longer displayed when the alarm cause has been removed. No other operator
actions are required.
Identifier
NCSTARTCLEAR
Effects
The alarm is cleared by starting a program in the channel, in which the alarm occurred. The alarm is
also cleared by an NC reset.
● Clear the alarm with the "CYCLE START" key or the RESET key and continue the program.
Identifier
POWERONCLEAR
Effects
The alarm is canceled by switching off the control and switching it on again.
● Switch the control OFF - ON.
Identifier
RESETCLEAR
Effects
The alarm is cleared by pressing the Reset key in the channel in which the alarm occurred.
● Clear the alarm with the RESET key. Restart the part program.
Identifier
BAGRESETCLEAR
Effects
The alarm is cleared by a "BAGRESETCLEAR" command or by carrying out a reset in all channels of
this mode group.
● Press the RESET key to clear the alarm in all channels of this mode group. Restart the part program.
Identifier
NCKRESETCLEAR
Effects
The alarm is cleared by an "NCKRESETCLEAR" command or by carrying out a reset in all channels.
● Clear alarm in all channels with the RESET key. Restart the part program.
532
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
Diagnostics Manual