Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Correct the specification of array elements in the access instruction to match the defined size. If an SPL is used in Safety
Integrated, the field index via optional data may be subject to additional restrictions.
Programm
Clear alarm with NC START or RESET key and continue the program.
continuation:
17030
[Channel %1: ] Block %2 illegal array index 2
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
General:
A read or write access has been programmed to an array variable with an invalid 2nd array index. The valid array indices
must lie within the defined array size and the absolute limits (0 - 32,766).
PROFIBUS I/O:
An attempt was made to read/write data outside the slot / I/O area limits of the stated slot / I/O area.
The following applies specifically: If the alarm occurs while writing one of the parameters
$TC_MDP1/$TC_MDP2/$TC_MLSR,
check whether MD18076 $MN_MM_NUM_LOCS_WITH_DISTANCE has been set correctly.
$MN_MM_NUM_LOCS_WITH_DISTANCE defines the number of different buffer storage locations that may be named in
Index2.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Correct the specification of array elements in the access instruction to match the defined size.
Programm
Clear alarm with NC START or RESET key and continue the program.
continuation:
17035
[Channel %1: ] Block %2 illegal array index 1
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
General:
A read or write access has been programmed to an array variable with an invalid 3rd array index. The valid array indices
must lie within the defined array size and the absolute limits (0 - 32,766).
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Correct the specification of array elements in the access instruction to match the defined size.
Programm
Clear alarm with NC START or RESET key and continue the program.
continuation:
17040
[Channel %1: ] Block %2 illegal axis index
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
A read or write access has been programmed to an axial variable in which the axis name cannot be unambiguously imaged
on a machine axis.
Example:
Writing of an axial machine data
$MA_... [X]= ... ; but geometry axis X cannot be imaged on a machine axis because of a transformation!
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
273