Remedy:
Assign unique name to swivel data block ($TC_CARR34[n]), if machine data 18088 $MN_MM_NUM_TOOL_CARRIER is
>1.
61181
[Channel %1: ] Block %2: NCK software version is insufficient for the Swivel function
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Swivelling is not possible with the current NCK software version.
Remedy:
Upgrade NCK software to NCK 75.00 or higher.
61182
[Channel %1: ] Block %2: Name of swivel data record unknown: %4
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The specified name of the swivel data block is unknown.
Remedy:
Check name of swivel data record $TC_CARR34[n].
61183
[Channel %1: ] Block %2: Swivel CYCLE800: Retraction mode parameter lies outside value range:
%4
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The value of the retraction mode parameter (_FR) lies outside the valid range.
Remedy:
Swivel CYCLE800: Check transfer parameter _FR. Value range 0 to 8
61184
[Channel %1: ] Block %2: No solution possible with current input angle values
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The surface defined via the input angle cannot be processed with the machine.
Remedy:
-Check the angles entered for swiveling the machining plane: %4
-Parameter _MODE coding incorrect, e.g. rotation axis-wise YXY
61185
[Channel %1: ] Block %2: Invalid angular ranges of rotary axes in swivel data record: %4
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The angular range of the rotary axes is invalid.
Check setup of the swivel CYCLE800.
Parameter $TC_CARR30[n] to $TC_CARR33[n] n number of swivel data record
Example: Rotary axis 1 modulo 360 degrees: -> $TC_CARR30[n]=0 $TC_CARR32[n]=360
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Check setup of swivel cycle CYCLE800.
Programm
Clear alarm with the RESET key. Restart part program
continuation:
61186
[Channel %1: ] Block %2: Invalid rotary axis vectors --> Check setup of the swivel cycle CYCLE800.
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
No or incorrect entry for rotary axis vector V1 or V2.