Siemens SINUMERIK 808D ADVANCED Diagnostic Manual page 240

Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
15910
[Channel %1: ] Block %2 touch probe not allowed
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Measure without deletion of distance-to-go
In the part program, an illegal probe has been programmed with the command MEAW (measure without distance-to-go).
The probe numbers
0 ... no probe
1 ... probe 1
2 ... probe 2
are allowed, whether the probe is actually connected or not.
Example:
N10 MEAW=2 G01 X100 Y200 Z300 F1000
Probe 2 without deletion of distance-to-go
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Include a probe number within the limits given above in the keyword MEAW=... This must correspond to the hardware
connection of the probe.
Programm
Clear alarm with NC START or RESET key and continue the program.
continuation:
15950
[Channel %1: ] Block %2 no traverse motion programmed
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Measure with deletion of distance-to-go
In the part program, no axis or a traversing path of zero has been programmed with the command MEAS (measure with
deletion of distance-to-go).
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Correct the part program and add the axis address or the traversing path to the measurements block.
Programm
Clear alarm with NC START or RESET key and continue the program.
continuation:
15960
[Channel %1: ] Block %2 no traverse motion programmed
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Measure without deletion of distance-to-go
In the part program, no axis or a traversing path of zero has been programmed with the command MEAW (measure without
deletion of distance-to-go).
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Correct the part program and add the axis address or the traversing path to the measurements block.
Programm
Clear alarm with NC START or RESET key and continue the program.
continuation:
16000
[Channel %1: ] Block %2 invalid value for lifting direction
Parameters:
%1 = Channel number
%2 = Block number, label
240
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
Diagnostics Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents