SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Explanation:
The active plane was changed between the first and second subblock when programming two straight lines with angle
parameters.
Reaction:
Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Modify part program.
Programm
Clear alarm with NC START or RESET key and continue the program.
continuation:
10791
[Channel %1: ] Block %2 invalid angle during linear programming
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
No intermediate point was found when programming a contour consisting of two straight lines and an angle specification.
Reaction:
Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Modify part program.
Programm
Clear alarm with NC START or RESET key and continue the program.
continuation:
10792
[Channel %1: ] Block %2 illegal interpolation type during linear programming with angles
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Only spline or linear interpolation is permitted for programming two straight lines with angle specification. Circular or
polynomial interpolation is not allowed.
Reaction:
Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Modify part program.
Programm
Clear alarm with NC START or RESET key and continue the program.
continuation:
10793
[Channel %1: ] Block %2 second block missing during linear programming with angles
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The second block is missing during programming of two straight lines with angle specification. This situation only occurs
if the first subblock is also the last block of a program, or if the first subblock is followed by a block with a preprocessor
stop.
Reaction:
Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Modify part program.
124